FAQ 1: Dab tsi yog qhov yuav tsum tau ntsuas hluav taws xob rau 11kV cable tiv thaiv kev ntsuas raws li IEC 60502-2?
Teb:Raws li covIEC 60502-2: 2tus qauv, AC tiv thaiv qhov ntsuas hluav taws xob rau cov cables nrog qhov ntsuas hluav taws xob ntawm 11kV (U0=11 kV) yog xam raws li3×U03×U0. Yog li ntawd, rau tus qauv 11kV cable, qhov yuav tsum tau kuaj voltage yog33kv ua. Siv a60kV VLF AC Hipot Test Setmuab ntau tshaj qhov nyiaj siv ua haujlwm txaus kom ua tau raws li tus qauv no thaum ua kom muaj kev nyab xeeb ntawm cov khoom siv thiab cov neeg siv khoom.
FAQ 2: Vim li cas VLF (Very Low Frequency) txoj kev yuav tsum tau ua rau niaj hnub XLPE cables?
Teb:Cov qauv thoob ntiaj teb, suav nrogIEC 60502-2: 2thiab IEEE 400.2, pom zoo rauAC VLF txoj kev (feem ntau 0.1Hz)dhau ib txwm DC kuaj rau XLPE (Cross-Txuas Polyethylene) cables. Kev ntsuam xyuas DC tuaj yeem ua rau "qhov chaw them nqi" tsub zuj zuj hauv cov rwb thaiv tsev, uas tuaj yeem ua rau tsis ua haujlwm ntxov ntxov tom qab nws rov qab mus rau qhov kev pabcuam. Kev ntsuam xyuas VLF muab qhov tseeb AC kev ntsuam xyuas kev ntxhov siab uas ua rau pom qhov cuam tshuam ntawm rwb thaiv tsev yam tsis muaj teeb meem polarization.
FAQ 3: Kuv puas tuaj yeem siv 60kV VLF Test Set rau 11kV thiab 33kV cable systems?
Teb:Yog lawm. A60kV VLF AC Hipot Test Setyog ntau yam heev. Txij li thaum 11kV cable yuav tsum tau kuaj 33kV thiab 33kV cable (U0=19 lossis 20 kVU0=19 lossis 20 kV) feem ntau xav tau qhov ntsuas hluav taws xob ze 57kV lossis 60kV, chav tsev tshwj xeeb no yog "qhov chaw qab zib" rau cov neeg ua haujlwm siv hluav taws xob. Nws tso cai rau koj los npog ob chav faib hluav taws xob ntau tshaj plaws nrog rau ib qho, portable ntaus ntawv.

FAQ 4: Txoj cai "33kV Test Voltage" yuav siv li cas rau cov kev teeb tsa tshiab thiab hauv -cov kev pabcuam cables?
Teb: IEC 60502-2: 2Feem ntau hais txog "Tom qab Kev Txhim Kho" (commissioning) theem, xav tau3U03U0 (33kV rau 11kV cables). Rau kev saib xyuas lossis "hauv- kev pabcuam" kev sim ntawm cov cables qub, qee qhov kev siv hluav taws xob tuaj yeem txo qhov hluav taws xob mus rau 2U02U0 lossis 2.5U02.5U0 txhawm rau tiv thaiv overstressing hnub nyoog rwb thaiv tsev. Txawm li cas los xij, rau kev ua tiav ntawm txoj haujlwm tshiab, ua tiav 33kV VLF lub hom phiaj yog kev lag luam kub tus qauv rau kev ntseeg tau.
FAQ 5: Dab tsi yog cov txiaj ntsig ntawm 0.1Hz zaus siv hauv koj chav 60kV VLF?
Teb:Cov0.1Hz zausyog "lub cev khawv koob" uas ua rau cov cuab yeej siv tau yooj yim. Ntawm 50Hz, kev sim 11kV cable ntev yuav xav tau lub tshuab hloov pauv loj vim tias muaj peev xwm siab. Los ntawm kev txo qhov zaus mus rau 0.1Hz, lubthem tam sim no yuav tsum tau txo los ntawm 500 zaug. Qhov no tso cai rau peb60kV VLF Hipot Test Setkom compact txaus rau kev siv teb thaum tseem xa cov ntshiab sinusoidal waveform uas ua tau raws li nruj metrology yuav tsum tau.