Ntsuas dielectric Loss yog ib txoj hauv kev hauv kev ntsuas rwb thaiv tsev, uas tuaj yeem pom qhov ua kom tsis zoo ntawm cov rwb thaiv tsev ntawm cov khoom siv hluav taws xob nrog rau cov teeb meem hauv zos. Nws yog dav siv hauv kev tsim hluav taws xob, khoom siv hluav taws xob teeb tsa, kev xa mus thiab kev kuaj kev tiv thaiv. Nws yog qhov yooj yim tshaj plaws los ntsuas qhov rwb thaiv tsev ntawm cov khoom siv hluav taws xob los ntawm kev ntsuas qhov dielectric poob ntawm nws cov transformers, ntsuas transformers, reactors, capacitors, bushing, thiab ntes.
Tan delta tester yog ib qho kev sib koom ua ke nrog cov khoom siv hluav taws xob hauv hluav taws xob tsis zoo, qhov sib txawv zaus voltage tswj fais fab mov, boost transformer, thiab SF6 high stability standard capacitor. Qhov kev ntsuam xyuas qhov hluav taws xob siab yog tsim los ntawm inverter hauv qhov ntsuas thiab yog siv rau qhov kev xeem tom qab tau txhawb nqa los ntawm lub transformer. Qhov zaus tuaj yeem hloov mus rau 50Hz, 47.5Hz \ 52.5Hz, 45Hz \ 55Hz, 60Hz, 57.5Hz \ 62.5Hz, 55Hz \ 65Hz, siv cov cuab yeej cuab tam digital, zam kev cuam tshuam ntawm lub zog zaus hluav taws xob teb ntawm qhov kev sim, kev daws teeb meem teeb meem ntawm kev ntsuas qhov tseeb nyob rau hauv kev cuam tshuam ntawm cov hluav taws xob muaj zog. Nyob rau tib lub sijhawm, nws yog qhov tsim nyog rau kev sim ntawm lub tshuab hluav taws xob fais fab tom qab tag nrho cov fais fab tuag. Qhov ntsuas tau nruab nrog lub khob roj insulated thiab ntsuas kub ntsuas ntsuas qhov dielectric poob ntawm cov roj insulated.
Transformer tan delta tester ua haujlwm video
Khoom Parameter
|
Work kev |
-15 degree ∽40 degree |
RH ~ 80% |
|
|
Txoj cai ntawm kev cuam tshuam |
Ntau zaus |
||
|
Fais fab mov |
AC 220V ± 10% Tawm tswv yim |
Tso cai generator |
|
|
Output high voltage |
0.5KV∽10KV (yuav ua tau 12kV) |
Txhua txhua 0.1kV |
|
|
Qhov tseeb |
2% |
||
|
Max tam sim no |
200 mA |
||
|
Capacitance |
2000 VA |
||
|
self-excitation fais fab mov |
AC 0V∽50V/15A |
50HZ, 60HZ ib zaus, 45HZ / 55HZ, 47.5HZ / 52.5HZ, 55HZ / 65HZ, 57.5HZ / 62.5HZ, Tsis siv neeg hloov dua siab tshiab |
|
|
daws teeb meem |
tgδ: 0.001% |
Cx: 0.001pF |
|
|
Qhov tseeb |
△tgδ:±(nyeem * 1.0%+0.040%) |
||
|
△C x : ±(nyeem*1.0%+1.00PF) |
|||
|
Kev xeem ntau yam |
tg tug |
Tsis muaj kev txwv |
|
|
C x |
15pF < Cx < 300nF |
||
|
10 KV |
Cx 60 nF |
||
|
5 kvu |
Cx 150 nF |
||
|
1 KV |
Cx 300 nF |
||
|
CVT test |
Cx 300 nF |
||
|
LCRxeem ntau yam |
L>20H (2kV) |
R>10KΩ (2kV) |
|
|
LCRkuaj qhov tseeb |
1% |
kev daws teeb meem angular |
0.01 |
|
CVTtig ratio range |
10∽10000 |
||
|
CVTtig ratio raug |
1% |
CVT tig ratio daws teeb meem |
0.01 |
|
size(host) (mm) |
350(L)×270(W)×270(H) |
||
|
size(akhoom siv) (mm) |
350(L)×270(W)×160(H) |
||
|
Lub peev xwm nco |
200 pab pawg Txhawb U disk cov ntaub ntawv khaws cia |
||
|
wyim(host) |
22.75 Kg |
||
|
wyim(akhoom siv) |
5.25 Kg |
||
|
Qauv |
JS-H |
JS-V |
JS-R |
|
UST hom |
√ |
√ |
√ |
|
GST hom |
√ |
√ |
√ |
|
CVT txoj kev npau suav |
√ |
√ |
√ |
|
C1/C2 xeem ib txhij |
|
√ |
√ |
|
External txheem voltage |
|
√ |
√ |
|
External high voltage |
|
√ |
√ |
|
CVT tig ratio |
|
√ |
√ |
|
CVT tes |
|
√ |
√ |
|
UST/GST xeem ib txhij |
|
√ |
√ |
|
LCR auto test |
|
√ |
√ |
|
Rwb thaiv tsev kuj kuaj |
|
|
√ |
|
USB kev sib txuas |
|
√ |
√ |
|
Udisk cia |
√ |
√ |
√ |
Khoom Feature Thiab Daim Ntawv Thov
1. Loj kov npo LCD zaub: yooj yim siv thiab tsis tas yuav cob qhia tus neeg siv, tsuas yog nyem qhov screen kom tiav tag nrho cov txheej txheem xeem
2. Lub peev xwm khaws cia siab, tuaj yeem txuag tau 200 pab pawg cov ntaub ntawv tau txais kev cawmdim hauv kev txiav txim siab, cov ntaub ntawv keeb kwm tuaj yeem pom txhua lub sijhawm, thiab tuaj yeem luam tawm;
3. Kev tswj cov ntaub ntawv: Cov ntaub ntawv ntsuas tuaj yeem xa tawm los ntawm U disk, thiab tuaj yeem saib thiab tswj ntawm txhua lub PC.
4. Multiple test modes: It can be tested by internal high voltage, external high voltage, internal standard, external standard, positive connection method, reverse connection method, self-excitation method, and other methods, High voltage (>10kV) dielectric poob tuaj yeem ua tau raws li cov txheej txheem sab nraud sab nraud siab voltage.
5. CVT xeem: tuaj yeem kuaj CVT (capacitor voltage transformer) C1 / C2 ntawm dielectric poob thiab capacitance, tuaj yeem kuaj C1 / C2 ib txhij. Kuj tseem tuaj yeem kuaj CVT Variation ratio thiab voltage Angle txawv;
6. tsis tas yuav tshem tawm cov high voltage cable los kuaj CVT: tuaj yeem kuaj CVT dielectric poob thiab capacitance tsis tas yuav tshem HV cable
7. CVT Rov qab kev sib txuas tiv thaiv kev ntsuas C0: tuaj yeem kuaj tus nqi dielectric poob thiab capacitance tus nqi ntawm CVT sab sauv C0
8. high-speed sampling teeb liab: Lub inverter thiab sampling Circuit Court nyob rau hauv lub ntsuas yog tag nrho cov tswj digitally, thiab cov zis voltage yog tsis tu ncua adjustable.
9. LCR tag nrho nws pib kuaj: Tsis siv neeg tso saib inductance, capacitance, tsis kam ntsuas, Lub kaum sab xis.
10. Ntau yam kev tiv thaiv nta: xws li input voltage fluctuation, high voltage tam sim no, tso zis luv luv Circuit Court, fais fab mov txhaum, overvoltage, overcurrent thiab kub, thiab lwm yam., los xyuas kom meej kev ruaj ntseg thiab kev cia siab ntawm lub ntsuas. kuj tau nruab nrog lub grounding detection muaj nuj nqi los xyuas kom meej tias cov khoom siv ungrounded tsis pub voltage boost.
Kev Paub meej



Accessory
|
Serial Number |
Lub npe |
Tus nqi |
|
1 |
tsis delta tester |
ib |
|
2 |
High voltage cable |
ib |
|
3 |
Tsawg voltage cable |
ob |
|
4 |
Cov kab hluav taws xob |
ib |
|
5 |
av lead |
ib |
|
6 |
CVT Kab |
ib |
|
7 |
5A Fuse (Internal) |
ob |
|
8 |
Printing ntawv (50ml) |
ib |
|
9 |
Specification |
ib |
|
10 |
Daim ntawv tshuaj ntsuam xyuas |
ib |
|
11 |
Daim ntawv pov thawj |
ib |
FAQ
1. Kev xa khoom:Kev xa khoom sai thiab hloov pauv hom kev thauj mus los
2. Kev Them Nyiaj:Xaiv cov nqe lus them nqi thiab kev them nyiaj uas koj yooj yim
3. Kev muag khoom:24-teev kev sib cuag hauv online, Xaiv cov qauv tsim khoom raws li koj qhov kev thov, muab qhov zoo tshaj plaws, txhawb kev hloov kho
4. Lub sijhawm lav:Tag nrho cov tshuab zoo guarantees rau ib xyoos thiab lub neej kev pab txhawb nqa rau koj. Online teb rau cov neeg siv khoom 'kev teeb meem.
Neeg tuaj xyuas

Peb qhov kev pabcuam
01
Kev pabcuam ua ntej muag
Ua kev sib tham txog cov khoom lag luam, kev tshaj tawm cov khoom lag luam, thiab kev ua lag luam, thiab kev txhawb nqa rau cov neeg siv khoom xav tau.
02
Kev pabcuam xa khoom
Ntim nrog ntoo rooj plaub, muab cov kev daws teeb meem sib txawv ntawm txoj kev xa khoom, txais kev them nyiaj sib txawv. Txuag tus nqi shipping thiab xyuas kom cov khoom tuaj txog zoo.
03
Kev pab cuam tom qab muag
Installation thiab commissioning ntawm tej yam khoom; Teb rau cov lus nug ntawm cov neeg siv khoom, teb cov lus nug ntawm cov neeg siv khoom, thiab daws cov lus nug ntawm cov neeg siv khoom.

Cim npe nrov: Tuam Tshoj Transformer Tan delta Tester manufacturers, lwm tus neeg, Hoobkas